Search for collections on University of Merdeka Malang Repository

A Study of LoRa Performance in Monitoring of Patient s SPO2 and Heart Rate based IoT

Adi, Puput Dani Prasetyo ORCID: https://orcid.org/0000-0002-5402-8864 and Kitagawa, Akio (2020) A Study of LoRa Performance in Monitoring of Patient s SPO2 and Heart Rate based IoT. International Journal of Advanced Computer Science and Applications (IJACSA), 11 (2). pp. 238-251. ISSN 2156-5570 (e) ; 2158-107X (p)

[thumbnail of 6.Karya tulis 6--A_Study_of_LoRa_Performance_in_Monitoring_of_Patients_SPO2.pdf]
Preview
Text
6.Karya tulis 6--A_Study_of_LoRa_Performance_in_Monitoring_of_Patients_SPO2.pdf

Download (2MB) | Preview
[thumbnail of Turnitin-6-A Study of LoRa Performance in Monitoring of Patient’s SPO2.pdf]
Preview
Text
Turnitin-6-A Study of LoRa Performance in Monitoring of Patient’s SPO2.pdf

Download (5MB) | Preview
[thumbnail of Peer Review (2).pdf]
Preview
Text
Peer Review (2).pdf

Download (565kB) | Preview

Abstract

Abstract—In this research, a sensor that will be equipped with blood oxygen saturation function (SPO2) blood and Heart Rate is MH-ET Live max30102 Sensor with Library Max30105. The advantage of this sensor is compatible with ATmega 328P, which is the Arduino board, the first experiment using Arduino Uno. Therefore, MH-ET Sensor data is integrated with Wireless Sensor Network (WSN) devices, e.g, LoRa (Long Range) 915 MHz and calculate WSN path loss when sending sensor data in mountainous areas, the model used to represent signal analysis and measurements in this study is the Ground Reflection (2-ray) model. therefore, the conditions that can be explained are patients who will send their data over hilly areas and hospitals or medical treatments called receiving nodes or coordinator nodes in much lower areas, in the same situation adding routers is expected to be a comparison of whether the data sent faster or even no impact. Furthermore, in this study, it is expected to provide clear results on the function of the router as the sender of pulse sensor data. The point is patients who are in a higher area with the level of impossibility in bringing the patient due to the condition of the patient so that the SPO2 data transmission and heart rate of the patient are expected to be known quickly by the medical authorities through the sensor node device attached to the patient's body. The use of the Adaptive Data Rate (ADR) Algorithm is used to optimize data rate, time on air (ToA) or airtime and energy consumption in the network. Therefore, the End Device (ED) in the ADR algorithm must be static (non-mobile). In the process of measuring the ADR algorithm in the position of sending data (uplink) n-bits to n-gateway. Next, the application server used is ThingsSpeak or The Things Network (TTN).

Item Type: Article
Additional Information: Puput Dani Prasetyo Adi NIDN: 1231128501
Uncontrolled Keywords: Pulse; heart rate; adaptive; data rate; long range; bitrate
Subjects: R Medicine > RA Public aspects of medicine > RA0421 Public health. Hygiene. Preventive Medicine
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Teknik > S1 Teknik Elektro
Depositing User: Rita Juliani
Date Deposited: 29 Oct 2021 02:49
Last Modified: 27 Dec 2021 12:39
URI: https://eprints.unmer.ac.id/id/eprint/972

Actions (login required)

View Item View Item