Search for collections on University of Merdeka Malang Repository

Pengaruh Kadar Serat Kawat Galvanis terhadap Kuat Tekan dan Kuat Tarik Belah Beton Mutu Tinggi dengan Filler Batu Apung

Izza, Rohmatul (2023) Pengaruh Kadar Serat Kawat Galvanis terhadap Kuat Tekan dan Kuat Tarik Belah Beton Mutu Tinggi dengan Filler Batu Apung. Undergraduate thesis, Fakultas Teknik Universitas Merdeka Malang.

[thumbnail of COVER.pdf] Text
COVER.pdf

Download (585kB)
[thumbnail of BAB I.pdf] Text
BAB I.pdf

Download (319kB)
[thumbnail of BAB II.pdf] Text
BAB II.pdf
Restricted to Repository staff only

Download (648kB)
[thumbnail of BAB III.pdf] Text
BAB III.pdf
Restricted to Repository staff only

Download (879kB)
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Repository staff only

Download (1MB)
[thumbnail of BAB V.pdf] Text
BAB V.pdf
Restricted to Repository staff only

Download (194kB)
[thumbnail of DAFTAR PUSTAKA.pdf] Text
DAFTAR PUSTAKA.pdf

Download (198kB)
[thumbnail of SK DAN HASIL CEK PLAGIASI.pdf] Text
SK DAN HASIL CEK PLAGIASI.pdf

Download (1MB)

Abstract

Concrete is weak against tensile forces. So, innovations such as the addition of fibers to concrete are needed to compensate for its weakness. One that can be used is fiber from galvanized wire. Galvanized wire with a diameter of 0.2 cm cut into 12 cm pieces was added to a mixture of high-strength concrete with a facade of 0.26 with galvanized wire fiber content of 0%, 4%, 6%, 8% and 10% by weight of cement. Pumice filler was added at 10% by weight of cement. The planned compressive strength is 50 MPa. The cylindrical specimens were 35 pieces. Testing compressive strength and split tensile strength is done when the concrete is 28 days old. From the analysis and calculation of the compressive strength of concrete with 0%, 4%, 6%, 8% and 10% fiber content respectively are 53.10, 56.34, 58.78, 62.89, and 60.24 (MPa) and the split tensile strength value obtained 5.31, 6.72, 6.87, 7.2, and 6.64 (MPa). The addition of 8% galvanized wire fiber content obtained the highest compressive strength and split tensile strength values with an increase of 9.79 MPa and 1.89 MPa respectively from concrete specimens without galvanized wire fiber.

Item Type: Thesis (Undergraduate)
Additional Information: Rohmatul Izza NIM : 19041000098
Uncontrolled Keywords: Concrete, fiber, compressive strength, split tensile strength and galvanized wire
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TP Chemical technology
Divisions: Fakultas Teknik > S1 Teknik Sipil
Depositing User: Gendhis Dwi Aprilia
Date Deposited: 05 Mar 2025 08:42
Last Modified: 05 Mar 2025 08:42
URI: https://eprints.unmer.ac.id/id/eprint/4465

Actions (login required)

View Item View Item