Pengaruh Faktor Air Semen dan Kadar Filler Material Kuarsa terhadap Kuat Tekan Mortar Beton Mutu Tinggi

Tania, Hilmi Kasifah Nora (2022) Pengaruh Faktor Air Semen dan Kadar Filler Material Kuarsa terhadap Kuat Tekan Mortar Beton Mutu Tinggi. Undergraduate thesis, Fakultas Teknik Universitas Merdeka Malang.

[thumbnail of COVER.pdf]
Preview
Text
COVER.pdf

Download (1MB) | Preview
[thumbnail of BAB I.pdf]
Preview
Text
BAB I.pdf

Download (183kB) | Preview
[thumbnail of BAB II.pdf] Text
BAB II.pdf
Restricted to Repository staff only

Download (538kB)
[thumbnail of BAB III.pdf] Text
BAB III.pdf
Restricted to Repository staff only

Download (745kB)
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Repository staff only

Download (1MB)
[thumbnail of BAB V.pdf] Text
BAB V.pdf
Restricted to Repository staff only

Download (94kB)
[thumbnail of DAFTAR PUSTAKA.pdf]
Preview
Text
DAFTAR PUSTAKA.pdf

Download (232kB) | Preview
[thumbnail of HASIL CEK PLAGIASI.pdf]
Preview
Text
HASIL CEK PLAGIASI.pdf

Download (1MB) | Preview

Abstract

In the development of concrete construction, concrete is required to be a high-quality construction material. However, because it uses a large amount ofcement, making high-quality concrete a material that is not environmentallyfriendly. The cement content in high-strength concrete is between 700-1100 kg/m³,and its use is almost 3 times more than the use of cement in conventionalconcrete. Remember that component Quartz filler material in the manufacture ofhigh-strength concrete is very good because it contains compounds such ascement constituents. This led to a new method using silica fume and quartz fillermaterial with high levels as cement additives, reducing waste, and makingconcrete environmentally friendly because it reduces CO2 emissions .
In this study, the compressive strength of concrete was tested on mortar specimens measuring 5 x 5 x 5 cm. The test was carried out when the concretewas 28 days old. The use of semen factor variation 0.35; 0.4; 0.45 and variationsin filler content of 5%, 10%, 15%, 20%. There were 75 test objects and dividedinto 4 populations. Testing the compressive strength of concrete using acompression testing machine based on the ASTM C579-01 standard.
The results showed that the concrete mortar specimen with the influence ofwater cement factor variation of 0.35 and zone 2 sand gradation had the highestaverage compressive strength of 67,040 MPa with a quartz filler of 15%. Whilethe normal test object without filler has the highest average compressive strengthof 66,161 MPa using a water cement factor of 0.35 and a sand gradation of zone2 . voids in concrete mortar caused by interlocking between fine aggregates sothat the concrete mortar becomes denser and produces high compressive strength.

Item Type: Thesis (Undergraduate)
Additional Information: Hilmi Kasifah Nora Tania NIM : 18041000094
Uncontrolled Keywords: Compressive Strength, High Strength Concrete Mortar, Water Cement Factor, Sand Gradation, Quartz Filler
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TH Building construction
Divisions: Fakultas Teknik > S1 Teknik Sipil
Depositing User: Gendhis Dwi Aprilia
Date Deposited: 16 Feb 2025 05:45
Last Modified: 16 Feb 2025 05:45
URI: https://eprints.unmer.ac.id/id/eprint/4331