Search for collections on University of Merdeka Malang Repository

Pengaruh Tebal Selimut Beton Terhadap Laju Korosi Baja Tulangan Dan Momen Lentur Balok Beton Bertulang Terkorosi

Nu'u, Anastasia (2024) Pengaruh Tebal Selimut Beton Terhadap Laju Korosi Baja Tulangan Dan Momen Lentur Balok Beton Bertulang Terkorosi. Undergraduate thesis, Fakultas Teknik Sipil Universitas Merdeka Malang.

[thumbnail of HALAMAN AWAL.pdf]
Preview
Text
HALAMAN AWAL.pdf

Download (3MB) | Preview
[thumbnail of BAB 1.pdf]
Preview
Text
BAB 1.pdf

Download (462kB) | Preview
[thumbnail of BAB 2.pdf] Text
BAB 2.pdf
Restricted to Repository staff only

Download (995kB)
[thumbnail of BAB 3.pdf] Text
BAB 3.pdf
Restricted to Repository staff only

Download (1MB)
[thumbnail of BAB 4.pdf] Text
BAB 4.pdf
Restricted to Repository staff only

Download (1MB)
[thumbnail of BAB 5.pdf] Text
BAB 5.pdf
Restricted to Repository staff only

Download (221kB)
[thumbnail of Daftar Pustaka.pdf]
Preview
Text
Daftar Pustaka.pdf

Download (455kB) | Preview
[thumbnail of Hasil Cek Plagiasi.pdf]
Preview
Text
Hasil Cek Plagiasi.pdf

Download (1MB) | Preview
[thumbnail of Hasil Cek Plagiasi.pdf]
Preview
Text
Hasil Cek Plagiasi.pdf

Download (1MB) | Preview

Abstract

Corrosion of reinforcing steel affects the strength of the structure. Reinforcing steel that rusts causes the function of the reinforcement to decrease. This study aims to determine the effect of the thickness of concrete blankets as reinforcement protection on the corrosion rate of reinforcing steel and the bending moment of corroded reinforced concrete beams, using test specimens measuring 15 x 15 x 65
cm with a concrete quality of 20.75 Mpa. The thickness of the concrete blanket used in this study is 10 mm, 15 mm and 25 mm with each thickness there are 5 test pieces. To accelerate the corrosion of reinforcement, 3.5% NaCl solution and
galvanostatic method were used. The tests carried out were bending moments carried out at 28 days of concrete age based on ASTM C78/C78M and corrosion date testing based on ASTM G 31-72 weight loss method. The highest bending
moment was 5.50 kNm in the reinforced concrete beam with 25 mm concrete blanket thickness and the lowest was 4.68 kNm in the reinforced concrete beam with 10 mm concrete blanket thickness. The highest corrosion rate was 28214.63
mpy in reinforced concrete beams with concrete blanket thickness of 10 mm and the lowest was 3977.34 mpy in reinforced concrete beams with concrete blanket thickness of 25 mm.

Item Type: Thesis (Undergraduate)
Additional Information: Anastasia Nu’u NIM: 20041000067
Uncontrolled Keywords: Bending Moment, Corrosion Rate, Concrete Blanket, Reinforcing Steel, Reinforced Concrete Beam
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TH Building construction
Divisions: Fakultas Teknik > S1 Teknik Sipil
Depositing User: fufu Fudllah Wahyudiyah
Date Deposited: 16 Feb 2025 00:57
Last Modified: 16 Feb 2025 00:58
URI: https://eprints.unmer.ac.id/id/eprint/4317