Implementasi Metode Fuzzy Untuk Mempertahankan Suhu dan Kelembapan Pada Kandang Ayam

Wahid, Lalu Abdurrahman, Sumarahinsih, Andrijani and Gumilang, Yandhika Surya Akbar ORCID: https://orcid.org/0000-0001-7894-0076 (2023) Implementasi Metode Fuzzy Untuk Mempertahankan Suhu dan Kelembapan Pada Kandang Ayam. In: Seminar Nasional Teknik Industri (SEMNASTI) 2023 : Effective, Efficient, Resilient Productivity In Global Disruption Era, 2023, Universitas PGRI Adi Buana Surabaya.

[thumbnail of 2. _Implementasi Metode Fuzzy Untuk Mempertahankan Suhu dan Kelembapan Pada Kandang Ayam_ Seminar Nasional Teknologi Industri Vol 1 No. 1 pp 256-264 Penulis Anggota.pdf]
Preview
Text
2. _Implementasi Metode Fuzzy Untuk Mempertahankan Suhu dan Kelembapan Pada Kandang Ayam_ Seminar Nasional Teknologi Industri Vol 1 No. 1 pp 256-264 Penulis Anggota.pdf

Download (566kB) | Preview
[thumbnail of 2. Hasil Cek Turnitin _Implementasi Metode Fuzzy Untuk Mempertahankan Suhu dan ....pdf]
Preview
Text
2. Hasil Cek Turnitin _Implementasi Metode Fuzzy Untuk Mempertahankan Suhu dan ....pdf

Download (600kB) | Preview

Abstract

The temperature and humidity of a closed house chicken coop are crucial for the chickens to feel comfortable. To maintain the health and growth of the chickens, maintaining the ideal temperature and humidity is essential. For chicken coops aged 1 to 7 days, the ideal temperature is 34°C. For chickens aged 8 to 14 days, the ideal temperature is 30°C. For chickens aged 15 to 23 days, the ideal temperature is 28°C. And for chickens aged 24 to 30 days, the ideal temperature is 26.6°C. The average humidity should be maintained between 50% to 70%. In this article, the temperature and humidity of the chicken coop will be controlled using fans and lights, with the BME280 sensor used to measure the temperature and humidity. The sensor readings will affect the output of the Pulse Width Modulation (PWM) of the fans and the ON/OFF state of the lights. By using the fuzzy method for temperature and humidity control in the chicken coop, stability will be maintained. The testing of the BME280 sensor against the HTC-2 showed an average temperature error of 1.28% and an average humidity error of 1.68%.

Item Type: Conference or Workshop Item (Paper)
Additional Information: Yandhika Surya Akbar Gumilang NIDN: 0716029703
Uncontrolled Keywords: Temperature and Humidity, Close House Chicken Cage, Fuzzy Method
Subjects: Q Science > QA Mathematics > QA75 Electronic computers. Computer science
S Agriculture > SF Animal culture
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Teknik > S1 Teknik Elektro
Depositing User: Rita Juliani
Date Deposited: 29 Mar 2024 07:44
Last Modified: 29 Mar 2024 07:44
URI: https://eprints.unmer.ac.id/id/eprint/4172

Actions (login required)

View Item View Item