Search for collections on University of Merdeka Malang Repository

Pengaruh Kadar Serat Bambu Terhadap Kuat Lentur Dan Kuat Geser Balok Beton Non Pasir

Downloads

Downloads per month over past year

Moris, Omar Haykal (2024) Pengaruh Kadar Serat Bambu Terhadap Kuat Lentur Dan Kuat Geser Balok Beton Non Pasir. Undergraduate thesis, Fakultas Teknik Universitas Merdeka Malang.

[thumbnail of HALAMAN AWAL.pdf]
Preview
Text
HALAMAN AWAL.pdf

Download (3MB) | Preview
[thumbnail of BAB I.pdf]
Preview
Text
BAB I.pdf

Download (1MB) | Preview
[thumbnail of BAB II.pdf] Text
BAB II.pdf
Restricted to Repository staff only

Download (3MB)
[thumbnail of BAB III.pdf] Text
BAB III.pdf
Restricted to Repository staff only

Download (3MB)
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Repository staff only

Download (6MB)
[thumbnail of BAB V.pdf] Text
BAB V.pdf
Restricted to Repository staff only

Download (263kB)
[thumbnail of Daftar Pustaka.pdf]
Preview
Text
Daftar Pustaka.pdf

Download (448kB) | Preview
[thumbnail of HASIL CEK PLAGIASI.pdf]
Preview
Text
HASIL CEK PLAGIASI.pdf

Download (486kB) | Preview

Abstract

Making non-fibrous sand concrete beams is useful for overcoming concrete problems that are unable to withstand the flexural tensile strength of concrete. Research on fibrous non-sand concrete beams uses bamboo fibers. The aim of this study is to determine the effect of fiber content of bamboo on the flexural strength and shear strength of non-fibrous sand concrete beams.The research is a test of 15 beams measuring 15 × 15 × 70 cm. The fiber length of bamboo is 10 cm, fiber shape is straight, distribution of 1⁄2 Hb fiber with variations in fiber content is 0,2%, 0,6%, 0,8%, and 1% by weight of cement. The flexural strength and shear strength tests of the beams are carried out at the age of 28 days, using a test kit of Hydraulic Concrete Beam Testing with capacity of 100 kN. The testing is according to ASTM C-78/C78M standard concerning standard test method for flexural strength of concrete (using simple beam with third-point loading).The results of the flexural strength and shear strength tests show that the variations in fiber content of bamboo 0,2% obtain the biggest flexural strength of 2.19 Mpa and shear strength of 0.41 Mpa. It is concluded that the variation in fiber content of bamboo 0,2% is the best flexural strength and shear strength.

Item Type: Thesis (Undergraduate)
Additional Information: Omar Haykal Moris NIM : 19041000087
Uncontrolled Keywords: Flexural strength, shear strength, non-sand concrete, bamboo fiber, fiber content
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Fakultas Teknik > S1 Teknik Sipil