Search for collections on University of Merdeka Malang Repository

Analisis Distribusi Aliran pada Pipa Distribusi Sistem Irigasi Tetes (Studi Kasus: Kampung Glintung Water Street (GWS) RW 05 Kelurahan Purwantoro, Kecamatan Blimbing, Kota Malang)

Downloads

Downloads per month over past year

Kurniasari, Marisa Wahyu (2024) Analisis Distribusi Aliran pada Pipa Distribusi Sistem Irigasi Tetes (Studi Kasus: Kampung Glintung Water Street (GWS) RW 05 Kelurahan Purwantoro, Kecamatan Blimbing, Kota Malang). Undergraduate thesis, Fakultas Teknik Universitas Merdeka Malang.

[thumbnail of HALAMAN AWAL.pdf]
Preview
Text
HALAMAN AWAL.pdf

Download (1MB) | Preview
[thumbnail of BAB I.pdf]
Preview
Text
BAB I.pdf

Download (207kB) | Preview
[thumbnail of BAB II.pdf] Text
BAB II.pdf
Restricted to Repository staff only

Download (606kB)
[thumbnail of BAB III.pdf] Text
BAB III.pdf
Restricted to Repository staff only

Download (701kB)
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Repository staff only

Download (676kB)
[thumbnail of BAB V.pdf] Text
BAB V.pdf
Restricted to Repository staff only

Download (206kB)
[thumbnail of DAFTAR PUSTAKA.pdf]
Preview
Text
DAFTAR PUSTAKA.pdf

Download (208kB) | Preview
[thumbnail of HASIL CEK PLAGIASI.pdf]
Preview
Text
HASIL CEK PLAGIASI.pdf

Download (1MB) | Preview

Abstract

In an attempt to maintain the continuity of food production, Glintung Water Street (GWS) applied a drip irrigation system on melon plants. Drip irrigation system isa way of distributing water from the main pipe through emitters that are distributed through the flow in the piping network. The water requirement of melon plants fordrip irrigation is about 1-2 liters/day per plant. Therefore, the purpose of this studyis to analyze the flow distribution in the pipe to 15 drip irrigation points in achieving the desired flow rate, which is 30 liters per day. The research used an experimental quantitative method, with data obtained including flow velocity, irrigation flow discharge data, and droplet uniformity. The results showed that the flow distribution in the pipes to 15 drip irrigation points met the desired flow discharge, which is 30 liters per day in the Glintung Water Street (GWS) village. However, the distribution of flow discharge at each irrigation point is different. In addition, the uniformity of water distribution shows differences in the uniformity criteria of each irrigation point, with an average uniformity of 91.78%.

Item Type: Thesis (Undergraduate)
Additional Information: Marisa Wahyu Kurniasari NIM : 20041000012
Uncontrolled Keywords: Drip Irrigation System, Flow Distribution, Flow Discharge, Distribution Uniformity, Glintung Water Street (GWS)